Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FBR X G os 2003 TC S - Burners & Combustion
FBRBurners & Combustion

FBR X G os 2003 TC S

FBR X G os 2003 TC S is a single-stage light-oil burner designed for cast iron boilers, delivering 23.7–39.1 kW thermal power with a 77 mm nozzle. Operating at 50Hz with 220 W nominal power, it suits heating and…

SKU 3G-FBR-00035

Brand
FBR
Item
X G os 2003 TC S
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FBR
Weight
11 kg
stage
Single stage for cast iron boilers
fuel type
Light oil
nozzle mm
77
fan motor w
100
preheater w
30-110
power kw max
39.1
power kw min
23.7
flow kg h max
3.3
flow kg h min
2
ip protection
IP 40
noisiness dba
57-59
electrical supply
1
power supply info
50Hz
current absorption a
1
thermal power mcal h
20.4-51
nominal electric power w
220
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S Light-oil burners single stage. They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head specific for cast iron boilers and combustion chambers with small length. Micro adjustment of the head, high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. In the versions H hydraulic device of closing air shutter. In the versions R preheater with control of temperature for soft and sicure ignitions also at low temperatures. On demand specific versions: kerosene, biodiesel. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G 0S Fig. 2 G 1S G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en TECHNICAL DATA G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S MODEL G 0HR G 0H G 1HR G 1H G 0SR G 0S G 1SR G 1S Flow min. - max. * [kg/h] 1.2-3.1 2.0-3.3 2.0-5.0 2.0-5.0 Thermal power min. - max. * [Mcal/h] 12.2-31.6 20.4-33.7 20.4-51 20.4-51 Thermal power min. - max. * [kW] 14.2-36.7 23.7-39.1 23.7-59.2 23.7-59.2 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 190 120 220 130 Fan motor [W] 90 90 100 100 Nominal current absorption [A] 0.9 0.6 1 0.6 Pre-heater [W] 30-110 - 30-110 - Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [dBA] 56-58 56-58 57-59 57-59 Burner weight [kg] 9 9 11 11 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). OPERATING RANGE DIAGRAM G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en DIMENSIONS [MM] Fig. 4 Dimensions G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S MODEL A B C D E F G H I G0...2003 137 137 240 83 223 169 15 150 150 G1...2003 157 170 275 83 265 210 15 150 150 * See "flame tube length" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L* L max M N min N* N max G0...2003 mm 130 150 170 M8 90 110 130 G1...2003 mm 130 150 170 M8 90 110 130 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** G0...2003 mm 112 152 G1...2003 mm 112 152 ** For different flame lengths, please contact our Technical-Sales Department. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners one stage. DETAILED SPECIFICATION Light-oil burner one stage composed by: • Aluminium frame; • Combustion head specific for cast iron boilers and combustion chambers with small length; • Micro adjustment of the head, high efficiency and high flame stability; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR X G os 2003 TC S is a single-stage light-oil burner designed for cast iron boilers, delivering 23.7–39.1 kW thermal power with a 77 mm nozzle. Operating at 50Hz with 220 W nominal power, it suits heating and industrial combustion applications.

Frequently Asked Questions

What is the FBR X G os 2003 TC S used for?

The FBR X G os 2003 TC S is a single-stage light-oil burner designed for cast iron boilers. It delivers 23.7–39.1 kW thermal power and is suitable for heating and industrial combustion applications in Singapore, including boiler systems for commercial buildings and process heating.

What are the specifications of the FBR X G os 2003 TC S?

The FBR X G os 2003 TC S is a single-stage light-oil burner with a 77 mm nozzle, 11 kg weight, and 220 W nominal electric power at 50 Hz. It has a fan motor of 100 W, preheater of 30–110 W, IP 40 protection, and noise level of 57–59 dBA. Fuel flow ranges from 2.0 to 3.3 kg/h.

Where to buy the FBR X G os 2003 TC S in Singapore?

You can source the FBR X G os 2003 TC S through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your site, providing technical support for installation and commissioning. Contact us for pricing and lead time on this FBR burner.

How to install the FBR X G os 2003 TC S burner?

Install the FBR X G os 2003 TC S by mounting the supplied flange and gasket on the boiler, connecting the 7-pole connector, and attaching flexible pipes and line filter. Ensure the combustion head is micro-adjusted for the chamber length. Follow the manufacturer's manual for electrical connections at 230 V, 50 Hz.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G IS 2003 TC S
FBR
X G IS 2003 TC S
X G OSR 2003 TC R S
FBR
X G OSR 2003 TC R S
X G os 2003 TXC S
FBR
X G os 2003 TXC S
X G 1SR 2003 TC R S
FBR
X G 1SR 2003 TC R S
X G X3 TC S
FBR
X G X3 TC S
G X3S TC S
FBR
G X3S TC S

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL