Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB180WHO-120-277V UV Ballast – Program Start

3G-OTH-03020 UV BALLAST – Program Start

SKU 3G-OTH-03020

Also listed as: UVB180WHO120277V · UVB180WHO 120 277V

Brand
Allanson
Item
UVB180WHO-120-277V UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
8.0"x3.0"x1.40"
Lamps
1 to 2
Weight
1.90 lb
Lamp mA
800
Lamp Type
High-output
Input Lamps
1 to 2
Lamp Length
24" to 64"
Potted Case
Yes
Input Voltage
120V-277V
Input Wattage
180

Datasheet Content

[{"filename":"3G-OTH-03020.pdf","text":"Specifications Sheet\n UV Ballasts\nUVB180WHO-120-277V\n1. Lamp Type\n Lamp Type / Cata # Manufacture # of Lamps Power (W) Current (mA)\n\n TUV PL-L95W/HO Philips 1-2 90 800\n\n GPH846T5 HO Light Sources 1-2 90 800\n\n TUV PL-L60W/HO Philips 1-2 60 680\n\n TUV64T5HO 4P-SE Philips 1 145 800\n\n\n2. Electrical\nBallast type: Program Start (PS) Power factor: > 95%\nNumber of lamps: 1 or 2 Efficiency: > 90%\nNormal input voltage: 120-277V, +/- 10%, 50-60 Hz Ballast shut down/protection: EOL/OC\nInput current: 1.50A (120V) / 0.70A (277V) Ambient temperature: 0 - 40° C\nInput current THD: < 10% Case maximum temperature: 75° C\nInput power: 180W @ full load Approvals: UL/cUL Listed, Class\nOperating frequency: > 25 kHz \"P\", Indoor, Type 1, CE\nLamp current crest factor: 1.7 or less Sound rating: “A”\n\n\n3. Wiring Diagram 4. Mechanical Data\n Dimensions: 8.0\" (L) x 3.0\" (W) x 1.40\" (H)\n\n\n\n\n5. Features\nTerminals are available for external LED to show lamp status: Purple (+), Grey (-); 2.5V.\n\n\n\n\n 83 Commerce Valley Drive East, Markham ON, L3T 7T3\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03020 UV BALLAST – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03020 UV ballast used for?

The Allanson 3G-OTH-03020 is a program-start UV ballast designed to power one or two high-output UV lamps, such as Philips TUV PL-L95W/HO or Light Sources GPH846T5 HO lamps. It is commonly used in water treatment, air purification, and industrial disinfection systems requiring reliable UV-C output.

What are the specifications of the Allanson 3G-OTH-03020?

The Allanson 3G-OTH-03020 operates at 120-277V, 50-60 Hz, with 180W input power at full load. It supports 1-2 lamps at 800 mA, lamp lengths from 24" to 64", and has a power factor above 95%. Dimensions are 8.0"x3.0"x1.40", and it is UL/cUL listed with CE approval.

Where to buy the Allanson 3G-OTH-03020 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03020 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quote and lead time on this program-start ballast.

How to install the Allanson 3G-OTH-03020 UV ballast?

Install the Allanson 3G-OTH-03020 by connecting input wires to a 120-277V supply per the wiring diagram. Mount the ballast in a dry, ventilated area with ambient temperature between 0-40°C. Use the purple (+) and grey (-) terminals for an external LED lamp-status indicator. Ensure proper lamp matching for 800 mA operation.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB160WHO-120-277V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-OD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-ID UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-PD UV Ballasts – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start