Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB120WHO-120-240V-OD UV Ballast – Program Start

3G-OTH-03009 UV BALLAST – Program Start

SKU 3G-OTH-03009

Also listed as: UVB120WHO120240VOD · UVB120WHO 120 240V OD

Brand
Allanson
Item
UVB120WHO-120-240V-OD UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
9.0″x1.90″x1.56″
Lamps
1
Weight
1.3 lb
Lamp mA
800
Lamp Type
High-output
Input Lamps
1
Lamp Length
24″ to 42″
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
120

Datasheet Content

[{"filename":"3G-OTH-03009.pdf","text":"Specifications Guide\n UV Ballasts\nUVB120WHO-120-240V-OD\n Lamp Type /Catalog # Manufacturer # of Lamps Power (W) Current (mA)\n\n GPH1148T5HO Light Source 1 120 800\n GPH1067T5HO Light Source 1 110 800\n TUV PL-L 95W/4P HO Philps 1 95 800\n TUV PL-L 60W/4P HO Philps 1 60 800\n TUV 36T5 HO Philps 1 75 800\n\n\nBallast Specifications\nBallast type: Program Start (PS) Power Factor: > 95%\nNumber of lamps: 1-2 Output Current: 800mA\nNormal input voltage: 120-240V, +/-10%, 50-60Hz Efficiency: > 90%\nInput current: 1.05A(120V)/0.53A(240V) Lamp Current Crest Factor: 1.7 or less\nInput power: 120W @ full load Striking/Ignition voltage: 1500 volt\nOperating frequency: > 30kHz Filament preheat time: 1.5-2.0 seconds\nIP Rating: IP 68 Ballast shut down/protection: EOL/OC\nEMI requirements: Meet FCC Part 18 Ambient temperature: 0-40ºC\nApprovals: UL/cUL Listed, Class “P”, Case maximum temperature: 75ºC\n Indoor, Type 1, CE Sound rating: “A”\n Weight: 1.30 lbs\n\n\nWiring Diagram and Dimensions BLUE LED\n\n Label\n GREEN LED 0.91\n\n\n 0.50\n 1.89\n\n\n 8.51\n\n 8.96\n\n\n 1.50 1.56\n\n Two diagnostic LEDs on ballast:\n Power on (Green), Lamp on (Blue)\n\n\n\n\n 83 Commerce Valley Dr. East, Thornhill, ON L3T 7T3\n allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03009 UV BALLAST – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03009 UV ballast used for?

The Allanson 3G-OTH-03009 is a program-start UV ballast designed to power high-output UV lamps in water treatment, air purification, and industrial disinfection systems. It supports lamps such as the GPH1148T5HO and TUV PL-L series, delivering 800 mA output current for reliable germicidal operation.

What are the specifications of the Allanson 3G-OTH-03009?

This Allanson ballast operates at 120-240 VAC, 50-60 Hz, with 120 W input power and 800 mA output current. It features program start, IP68 rating, UL/cUL and CE approvals, and diagnostic LEDs. Dimensions are 9.0 x 1.90 x 1.56 inches, weight 1.3 lb, and it supports one high-output lamp from 24 to 42 inches.

Where to buy the Allanson 3G-OTH-03009 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03009 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this program-start ballast for industrial UV systems.

How to install the Allanson 3G-OTH-03009 UV ballast?

Install the Allanson 3G-OTH-03009 by connecting input wires to a 120-240 VAC supply per the wiring diagram. Mount the ballast in a dry, ventilated area within 0-40 °C ambient temperature. Ensure proper lamp wiring for program start; the green LED indicates power, blue LED confirms lamp operation.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB120WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-ID UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB180WHO-120-277V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-120-240V UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start