Dwyer 3G-CBM-02224 — Technical Specifications
Dwyer PAFS-1002 average flow probe measures liquid flow in industrial piping systems with 4 detection points and 6 mm ID tubing connection. ABS/polycarbonate construction rated UL94-5V suits chemical and water applications requiring compact inline sensing.
Technical Specifications
| Parameter | Value |
|---|---|
| Material | ABS/polycarbonate (UL94-5V) |
| Mounting | Integral flange with gasket |
| Detection Points | 4 |
| Tubing Connection | 6 mm ID, 10 mm OD |
| Storage Temperature | -40 to +60°C |
| Operating Temperature | 4 to 49°C |
Physical & Shipping Data
| Weight | 0.028 kg |
| Length | 80.2 mm |
| Country of Origin | France |