Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start

UVB160WHO-120-277V-PD UV BALLASTS – Program Start

SKU 3G-OTH-03014

Also listed as: UVB160WHO120277VSS · UVB160WHO 120 277V SS

Brand
Allanson
Item
UVB160WHO-120-277V-SS UV Ballasts – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
8.5"1.75"1.25"
Lamps
1
Lamp mA
800
Lamp Type
High-output
Input Lamps
1
Lamp Length
24" to 64"
Potted Case
Yes
Input Voltage
100V-277V
Input Wattage
160

Datasheet Content

[{"filename":"3G-OTH-03014.pdf","text":"Specifications Guide\n UVB Ballasts\nUVB160WHO-120-277V-SS\n Lamp Type / Catalog # Manufacturer Power (W) Current (mA)\n\n GPH546T5HO/4P Light Sources 57 800\n GPH843T5HO/4P Light Sources 87 800\n GHO1224T5/4P Light Sources 110 800\n GPH1554T5HO/4P Light Sources 145 800\n TUV64T5HO Philips 145 800\n\n\nBallast Specifications\nBallast type: Program Start (PS) Power factor: > 95%\nNumber of lamps: 1 Efficiency: > 90%\nNormal input voltage: 100-277V, +/- 10% Ballast shut down/protection: EOL/OC\nFrequency: 47-63 Hz Open circuit volt: 800V\nInput Current: 1.38A(120V)/0.64A(277V) Preheat time: 2-5 seconds\nInput power: 160W @ full load Maximum ambient temperature: 65ºC\nOperating frequency: > 30kHz Case maximum temperature: 90ºC\nApprovals: UL/cUL Listed, Class “P”, Output lamp current: 800mA\n Indoor, Type 1\n\n\nWiring Diagram and Dimensions\n\n\n\n\nFeatures\nThe ballast will provide a selectable option to turn off the power by shorting two lead wires, and turn on\nthe power by opening the connection between the same two lead wires.\n\n\n\n\n 83 Commerce Valley Drive East, Markham, ON L3T 7T3\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

UVB160WHO-120-277V-PD UV BALLASTS – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03014 UV ballast used for?

The Allanson 3G-OTH-03014 is a program-start UV ballast designed to power single high-output UV lamps, such as GPH546T5HO/4P or TUV64T5HO, in water treatment, air purification, and industrial disinfection systems. It operates at 800 mA and supports lamp lengths from 24 to 64 inches.

What are the specifications of the Allanson 3G-OTH-03014?

This Allanson ballast accepts 100-277 VAC input, draws 1.38 A at 120 V or 0.64 A at 277 V, and delivers 160 W output at 800 mA. It features program start, >90% efficiency, >95% power factor, EOL/OC protection, and an open-circuit voltage of 800 V. It is UL/cUL listed for indoor use.

Where to buy the Allanson 3G-OTH-03014 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03014 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for pricing and lead time on this program-start ballast.

How to install the Allanson 3G-OTH-03014 ballast?

Mount the ballast in a dry, ventilated location away from heat sources. Connect input wires to a 100-277 VAC supply per the wiring diagram. The ballast supports a selectable remote on/off function by shorting two lead wires. Ensure the lamp matches the 800 mA rating and preheat time of 2-5 seconds.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB160WHO-120-277V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-PD UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB180WHO-120-277V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-OD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-ID UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB248T5-425-MV UV Ballast – Instant Start