Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB80WHO-120-240V-TAPD UV Ballast – Program Start

3G-OTH-03054 UV BALLASTS – Program Start

SKU 3G-OTH-03054

Also listed as: UVB80WHO120240VTAPD · UVB80WHO 120 240V TAPD

Brand
Allanson
Item
UVB80WHO-120-240V-TAPD UV Ballast – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
5.0"x3.0"x1.35"
Lamps
1
Weight
1.10 lb
Lamp mA
800
Lamp Type
High-output
Input Lamps
1
Lamp Length
8" to 21"
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
80

Datasheet Content

[{"filename":"3G-OTH-03054.pdf","text":"Specifications Sheet\n UV Ballasts\nUVB80WHO-120-240V-TAPD\n1. Lamp Type\n Lamp Type / Cata # Manufacture Power (W) Current (mA)\n G36T5L/HO/C First Light 75 800\n\n GHO463T5L/4 PIN Light Sources 51 800\n\n GHO275T5L/4 PIN Light Sources 30 800\n\n GHO212T5L/4 PIN Light Sources 23 800\n\n\n\n2. Electrical\nBallast type: Program Start (PS) Efficiency: > 90%\nNumber of lamps: 1 Ballast shut down/protection: EOL/OC\nNormal input voltage: 120-240V, +/- 10%, 50-60 Hz Status indication/alarm: Timer, buzzer, reset\nInput current: 0.66A (120V) / 0.33A(240V) switch, LEDs\nInput current THD: < 10% Ambient temperature: 0 - 40° C\nInput power: 80W @ full load Case maximum temperature: 75° C\nOperating frequency: > 25 kHz Approvals: UL/cUL Listed, Class \"P\",\nLamp current crest factor: 1.7 or less Indoor, Type 1\nPower factor: > 95% Sound rating: “A”\n\n\n\n3. Wiring Diagram 4. Mechanical Data\n\n\n\n\n5. Features\nThe ballast has implemented a microcontroller based timer, as well as alarm buzzer, and diagnostic LEDs for\nmonitoring/sensing both ballast/lamp operation, and lamp life time.\n\n\n\n\n 83 Commerce Valley Drive East, Markham ON, L3T 7T3\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03054 UV BALLASTS – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03054 UV ballast used for?

The Allanson 3G-OTH-03054 is a program-start UV ballast designed to power one high-output UV lamp, such as the G36T5L/HO/C, for water treatment, air purification, or industrial disinfection systems. It operates at 120-240 VAC and delivers 80 W input power.

What are the specifications of the Allanson 3G-OTH-03054?

The Allanson 3G-OTH-03054 is a program-start ballast for one high-output lamp (800 mA). Input voltage is 120-240 VAC ±10%, 50-60 Hz. Input power is 80 W, efficiency >90%, power factor >95%, and operating frequency >25 kHz. It includes EOL/OC protection and diagnostic LEDs.

Where to buy the Allanson 3G-OTH-03054 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03054 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this program-start ballast.

How to install the Allanson 3G-OTH-03054 UV ballast?

Mount the Allanson 3G-OTH-03054 in a dry, ventilated area with ambient temperature 0-40°C. Connect input wires to a 120-240 VAC supply per the wiring diagram. Ensure the lamp is compatible (e.g., G36T5L/HO/C). The ballast features a timer, buzzer, and diagnostic LEDs for monitoring.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB80WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB80W-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-OD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB60WHO-120-240V-TADP UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-ID UV Ballast – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start