Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
AllansonUV Ballasts

Allanson UVB60WHO-120-240V-TADP UV Ballasts – Program Start

3G-OTH-03049 UV BALLASTS – Program Start

SKU 3G-OTH-03049

Also listed as: UVB60WHO120240VTADP · UVB60WHO 120 240V TADP

Brand
Allanson
Item
UVB60WHO-120-240V-TADP UV Ballasts – Program Start
Category
UV Ballasts
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
8.15"x2.90"x1.80"
Lamps
1
Weight
3.10 lb
Lamp mA
800
Lamp Type
High-output
Input Lamps
1
Lamp Length
8" to 21"
Potted Case
Yes
Input Voltage
120V-240V
Input Wattage
60

Datasheet Content

[{"filename":"3G-OTH-03049.pdf","text":"Specifications Sheet\n UV Ballasts\nUVB60WHO-120-240V-TADP\n1. Lamp Type\n Lamp Type / Cata # Manufacture Power (W) Current (mA)\n GHO520T5L/4P Puretec 46 800\n GHO463T5L/4P Light Sources Inc. 51 800\n\n GHO275T5L/4P Light Sources Inc. 30 800\n\n GHO212T5L/4P Light Sources Inc. 23 800\n\n\n\n2. Electrical\nBallast type: Program Start (PS) Ballast shut down/protection: EOL/OC\nNumber of lamps: 1 Lamp life indication: 365 days timer counter\nNormal input voltage: 120-240V, +/- 10%, 50-60 Hz down with LED segment\nInput current: 0.50A (120V) / 0.25A( 240V) display\nInput current THD: < 10% Status indication/alarm: Red & blue LEDs, buzzer,\nInput power: 60W @ full load reset switch\nOperating frequency: > 25 kHz Ambient temperature: 0 - 40° C\nLamp curent crest factor: 1.7 or less Case maximum temperature: 75° C\nPower factor: > 95% Approvals: UL/cUL Listed, Class \"P\",\nEfficiency: > 90% Indoor, Type 1\n Sound rating: “A”\n\n3. Wiring Diagram 4. Mechanical Data\n\n\n\n\n5. Features\nThe ballast has implemented a microcontroller based timer counter down with LED segment display (365 days), as\nwell as alarm buzzer, and diagnostic LEDs for monitoring/sensing both ballast/lamp operation, and lamp life time.\n\n\n\n\n 83 Commerce Valley Drive East, Markham ON, L3T 7T3\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03049 UV BALLASTS – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03049 UV ballast used for?

The Allanson 3G-OTH-03049 is a program-start UV ballast designed to power one high-output UV lamp, such as the GHO520T5L/4P or GHO463T5L/4P, in water treatment, air purification, or industrial disinfection systems. It operates at 120-240V and 60W, with EOL/OC protection and a 365-day timer counter.

What are the specifications of the Allanson 3G-OTH-03049?

The Allanson 3G-OTH-03049 ballast supports one high-output lamp at 800 mA, input voltage 120-240V ±10%, 50-60 Hz, input power 60W, power factor >95%, efficiency >90%, and operating frequency >25 kHz. It measures 8.15"x2.90"x1.80", weighs 3.10 lb, and is UL/cUL listed, Class P, indoor Type 1.

Where to buy the Allanson 3G-OTH-03049 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03049 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this program-start ballast with 365-day timer and diagnostic LEDs.

How to install the Allanson 3G-OTH-03049 UV ballast?

Install the Allanson 3G-OTH-03049 by wiring per the manufacturer's diagram, ensuring input voltage is 120-240V ±10%. Mount in a dry, indoor location with ambient temperature 0-40°C and case max 75°C. Connect one high-output lamp (8" to 21") and verify the red/blue LEDs and buzzer for proper operation.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB80WHO-120-240V-TAPD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-OD UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-120-240V-TA UV Ballast – Program Start
Allanson
Allanson
Allanson UVB120WHO-120-240V-ID UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-PD UV Ballasts – Program Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start